    Intraocular Light Scatter in Eyes with Boston Type 1 Keratoprosthesis

    Thumbnail
    View/Open
    Main Article (63.91Kb)
    Date
    2018-08
    Author
    Karas, Faris I.
    Arteaga, Andrea
    Barrionuevo, Pablo
    Cao, Dingcai
    McAnany, J. Jason
    Shorter, Ellen
    Cortina, Maria S.
    Publisher
    Lippincott, Williams & Wilkins
    Metadata
    Show full item record
    Abstract
    Purpose: Boston Keratoprosthesis (KPro) is the most commonly used artificial cornea. It has been proven to be successful for severe corneal disease not amenable to keratoplasty. We have observed our patients complain of debilitating glare despite attaining good visual acuities. This motivated us to objectively measure light scatter in eyes with KPro. Methods: Light scatter was measured in 21 eyes with Boston KPro Type 1 with VA of 20/150 or better and was compared to 13 healthy control eyes using OCULUS C-Quant device (Arlington, WA). Eyes were also measured with the use of an occluder contact lens. Results: Light scatter (quantified as logS value) was significantly higher in the KPro group compared to the control (2.34 ± 0.15 vs. 1.29 ± 0.17, p < 0.001). PMMA KPro (16 eyes, logS 2.49 ± 0.19) but not the titanium group (5 eyes, logS 1.87 ± 0.15) had significantly higher light scattering than the control. The use of an occluder contact lens significantly decreased light scatter in eyes with PMMA-backplate (n=11, logS 1.71 vs 2.42, p =0.028). Conclusion: This study confirms that intraocular light scatter is increased in KPro eyes. Possibly due to its opaque nature, the titanium backplate model appears to produce less light scatter than PMMA model. Occluder contact lenses reduced the light scatter significantly in PMMA KPro and could be a treatment option for symptomatic patients.
    Citation
    Karas, F. I., Arteaga, A., Barrionuevo, P., Cao, D., McAnany, J. J., Shorter, E., & Cortina, M. S. (2019). Intraocular Light Scatter in Eyes With the Boston Type 1 Keratoprosthesis. Cornea, 38(1), 50-53. doi:10.1097/ICO.0000000000001724
    Subject
    Intraocular light scatter
    Glare
    Boston Keratoprosthesis (KPro)
    PMMA backplate
    titanium backplate
    Type
    Article
    Date available in INDIGO
    2019-05-23T18:37:41Z
    URI
    http://hdl.handle.net/10027/23433
    Collections
    • Publications - Ophthalmology and Visual Sciences

    DSpace software copyright © 2002-2015  DuraSpace
    Contact Us | Send Feedback | Privacy Statement
    Theme by 
    Atmire NV

    Browse

    All of INDIGOCommunities & CollectionsBy Issue DateAuthorsTitlesSubjectsThis CollectionBy Issue DateAuthorsTitlesSubjects

    My Account

    LoginRegister

    Statistics

    View Usage Statistics

    DSpace software copyright © 2002-2015  DuraSpace
    Contact Us | Send Feedback | Privacy Statement
    Theme by 
    Atmire NV